Pages

29/09/2018

Torque in the Synchronous Motor

Starting torque

  • It is torque developed by the synchronous motor when name plate voltage is applied to its armature winding. It is also called as breakdown torque. 
  • It may as low as 10% in the case of centrifugal pump.

Running torque

  • It is torque developed by the synchronous motor under running condition. It is determined by horse power and speed of the motor.
        P = Tω

Pull in torque

  • A synchronous motor is started as induction motor during starting condition and its speed below 2 to 5% of the synchronous speed. 
  • When the excitation ( or DC supply ) to the field winding is applied, the motor pull into synchronism resulting stator and rotor magnetic field rotates at same speed.
  • The amount of torque requires for synchronous motor to pull into synchronism is called as pull in torque.

Pull out torque

  • It is maximum torque which the synchronous motor can develop without pulling out of step. 
  • When the synchronous motor is loaded, the rotor falls back by some angle a is called as load angle. 
  • The stator and rotor magnetic rotates at synchronous speed in spite of some load is applied on the rotor. 
  • The synchronous motor developed maximum torque when the rotor falls back by angle 900
  • When the load increases beyond its maximum rating, the rotor steps out of synchronism and synchronous motor stop.

You may also like :




2 comments:

  1. Extremely useful information which you have shared here about motor. This is a great way to enhance knowledge for us, and also beneficial for us. Thank you for sharing an article like this.
    Linear induction motor

    ReplyDelete
  2. Very well written article. It was an awesome article to read. Complete rich content and fully informative. I totally Loved it.hydraulic companies in bangalore

    ReplyDelete